HPS Centurion® R CRX0011BC Air Core and Coil Line Reactor, 480 VAC, 11 A, 7-1/2 hp, 2.1 mH, 0.03 Impedance, 5.38 in H x 4.13 in W

Short Description

The new HPS Centurion® R reactor provides a unique blend of improved performance and reliability while reducing the product footprint. HPS Centurion® R reactors deliver protection for your motors and AC drives, while minimizing power system harmonics. They are available in standard ratings from 1/2 hp (373 W) to 1200 hp (895 kW), upto 600 VAC (690 VAC with de-rating) and are fully compliant with UL, CSA, CE, IEC and NEMA standards. The efficient and cost effective HPS Centurion® R reactors are built to satisfy the power quality needs of demanding AC drive applications.

HPS Centurion® R Line Reactor, Air Core and Coil, Series: CRX, 480 VAC, 11 A, 7-1/2 hp, 3 ph, 2.1 mH, 0.03 Impedance, 5.38 in Height, 4.13 in W, 3.51 in D, Floor/Panel Mount, Iron

MFG #: CRX0011BC

EECO #: HAMCRX0011BC

Brand: HPS Centurion R
UPC #: 803423117412
Attributes
Features
Documents
Product Information
Attributes
Phase
3
Impedance
0.03
Mounting Type
Floor/Panel
Voltage Rating
480
Type
Air Core and Coil
Depth
3.51
Width
4.13
Height
5.38
Series
CRX
Warranty
10 years
Horsepower
7-1/2
Inductance
2.1
Amperage Rating
11
UNSPSC
39121015
Material
Iron
Application
Oil and Gas, Irrigation Fields, Wastewater, Food Processing, Pharmaceutical, Steel, Pulp and Paper, HVAC and Automotive Applications
Features
  • The impedance of the reactors is accurately controlled by maintaining the core gaps in the flux path
  • In some HP ranges, bobbins are used to provide exceptional mechanical strength and increase the product reliability
  • Every reactor is vacuum pressure impregnated (VPI) with VT (vinyl-toluene) polyester resin to minimize audible noise
  • Rugged steel enclosures with UL 50 ANSI 61 gray paint
  • Finger proof terminal blocks are provided on rated currents of approximately below 65 A termination
  • Terminal pads are supplied on approximately 65 A and above, terminal pads are brazed to ensure electrical integrity
  • Mitigate nuisance tripping
  • Extend the life of switching components and motors
  • Reduce audible motor noise and motor operating temperature
  • Mitigate the effect of long lead length
  • Minimize harmonic distortion
  • Reduce line notching
  • Innovative design showcases a unique blend of performance and economy to protect your VFD, motor, capacitors and electrical system from harmonics, damage and nuisance tripping
  • Noise level between 58 to 75 dBA
HPS Centurion® R CRX0011BC Air Core and Coil Line Reactor, 480 VAC, 11 A, 7-1/2 hp, 2.1 mH, 0.03 Impedance, 5.38 in H x 4.13 in W