EATON N43M28T50XCU Type KT-13 Energy Efficient Non-Linear Ventilated Transformer, 416 V Primary, 208Y/120 V Secondary, 50 kVA Power Rating, 50/60 Hz, 3 ph

Short Description

EATON K-factor transformers address the problems caused by non-linear loads and harmonics. They also compensate for stresses on a transformers winding insulation which prevents insulation breakdown and premature failure. The net result is longer transformer life.

EATON Transformer, Type KT-13 Energy Efficient Non-Linear Ventilated, 416 V Primary, 208Y/120 V Secondary, 50 kVA Power, 50/60 Hz Frequency, 3 ph, 6 Taps, Lug Connection, 915D Frame Circuit, 220 deg C Insulation, NEMA 2 Enclosure, 150 deg C, Copper Winding, Steel Housing Material, 22 in L x 29 in W x 39 in H Dimensions
MFG #: N43M28T50XCU

EECO #: CHN43M28T50XCU

Brand: Eaton
UPC #: 786680064982
Attributes
Features
Documents
Product Information
Attributes
Temperature Rating
150
Phase
3
Connection Type
Lug
Enclosure Type
NEMA 2
Frequency Rating
50/60
Circuit Type
915D Frame
Housing Material
Steel
Includes
Bonding/Grounding Bar
Type
Type KT-13 Energy Efficient Non-Linear Ventilated
Warranty
1 year
Dimensions
22 in L x 29 in W x 39 in H
Primary Voltage
416
Secondary Voltage
208Y/120
UNSPSC
39121029
Number of Taps
6.0000
Application
Commercial, Institutional Buildings, Structures, Safety and Security Systems and Indoor Applications
Power Rating
50
Features
  • Includes transformers with DOE 2016 and NEMA TP-1 efficiency requirements and transformers with other efficiency requirements
  • Specially designed to withstand the harmful overheating effects caused by harmonics generated by nonlinear (non-sinusoidal) loads
  • Neutral bus size configured to accommodate at least 200% of the rated current compensates for increased neutral currents found in non-linear loads, thus reducing heat
  • Transformers include a versatile bonding/grounding bar affixed to the bottom panel as standard to provide compliance with NEC 450.10(A)
  • The core and coil assembly is grounded to the transformer enclosure by means of a visible flexible copper ground strap
  • Reduced core flux density
  • Coils designed to minimize stray losses
  • Electrostatic shield reduces transient noise in the system which may affect sensitive computer loads
Please note: This product is subject to geographic restrictions and can only be sold within the Carolinas.