Bussmann Fusetron™ FRS-R-3 Current Limiting Renewable Time Delay Fuse, 3 A, 600 VAC/300 VDC, 200 kA Interrupt, RK5 Class, Cylindrical Body

Short Description

600 VAC, 300 VDC, 3 A, Ferrule with Grooved Ring Terminal, Class RK5, 10 Sec Time Delay, UL Power Fuse

Bussmann Fusetron™ Time Delay Fuse, Current Limiting Renewable, Series: FRS-R, Indicating/Non-Indicating: Non-Indicating, Rejection/Non-Rejection: Rejection, 3 A, 600 VAC/300 VDC, 200 kA Interrupt, Class: RK5, 10 s at 500% Response, Ferrule Terminal, Holder Mount, Cylindrical Body Type, Dual Element, Fiberglass, 0.81 in Dia x 5 in L Body Size

MFG #: FRS-R-3

EECO #: BUFRSR3

Brand: Bussmann
UPC #: 051712507998
Attributes
Features
Documents
Product Information
Attributes
Class
RK5
Mounting Type
Holder
Response Time
10 s at 500%
Terminal Type
Ferrule
Voltage Rating
600 VAC/300 VDC
Approval
UL 248-12, CSA C22.2, CE
Current Rating
3 Amp
Characteristics
10 Second Time Delay (at 500 Percent Rated Load), Dual Element, Non-Indicating
Type
Current Limiting Renewable
Series
FRS-R
Amperage Rating
3
Diameter
0.81 Inch
UNSPSC
39121606
Material
Fiberglass
Application
Combination Starters, Machinery Disconnects, Motor Control Centers and Power Panelboard Applications, Safety and Security Systems
Interrupting Rating
200 Kiloamp Symmetrical (AC), 20 Kiloamp (DC)
Features
  • Dual element feature provides the best time delay performance, allowing closer sizing and superior protection of motors and transformers
  • Closer sizing allows for smaller fuses and less costly switches
  • Class RK5 fuses with a 200 kA interrupt rating for use in a broad range of applications
  • Provides motor overload, ground fault and short circuit protection
  • Helps protect motors against burnout from overloads and single phasing when sized properly
  • Dual element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance short circuit and overload protection
  • Offers a 10 sec time delay at 5 times the rated current
  • The time delay feature makes it possible to use fuse amperage ratings which are much smaller than those of non-time delay fuses
  • Considerable cost savings occur by permitting the use of smaller size switches, panels and fuses themselves
  • Provides current limitation to help protect downstream components from high fault currents
  • Gives motor running back-up protection to motors without extra cost
Qty Unit price
Ea
1 $26.71

Slpk
1 $26.71

Slqt
1 $26.71

Stpk
1 $267.10

Unit
1 $26.71
Please note: This product is subject to geographic restrictions and can only be sold within the Carolinas.
Bussmann Fusetron™ FRS-R-3 Current Limiting Renewable Time Delay Fuse, 3 A, 600 VAC/300 VDC, 200 kA Interrupt, RK5 Class, Cylindrical Body