Bussmann Fusetron™ FRS-R-175 Current Limiting Renewable Time Delay Fuse, 175 A, 600 VAC/300 VDC, 20/200 kA Interrupt, RK5 Class, Cartridge Body

Short Description

600 VAC, 300 VDC, 175 A, Blade Terminal, Class RK5, 10 Sec Time Delay, UL Power Fuse

Bussmann Fusetron™ Time Delay Fuse, Current Limiting Renewable, Series: FRS-R, Indicating/Non-Indicating: Non-Indicating, Rejection/Non-Rejection: Rejection, 175 A, 600 VAC/300 VDC, 20/200 kA Interrupt, Class: RK5, 10 s at 500% Response, Blade Terminal, Holder Mount, Cartridge Body Type, Dual Element, Fiberglass, 1.61 in Dia x 9.63 in L Body Size

MFG #: FRS-R-175

EECO #: BUFRSR175

Brand: Bussmann
UPC #: 051712508476
Attributes
Features
Documents
Product Information
Attributes
Class
RK5
Mounting Type
Holder
Response Time
10 s at 500%
Terminal Type
Blade
Voltage Rating
600 VAC/300 VDC
Approval
UL 248-12, CSA C22.2, CE
Current Rating
175 Amp
Characteristics
10 Second Time Delay (at 500 Percent Rated Load), Dual Element, Non-Indicating
Type
Current Limiting Renewable
Series
FRS-R
Amperage Rating
175
Diameter
1.84 Inch
UNSPSC
39121606
Material
Fiberglass
Application
Combination Starters, Machinery Disconnects, Motor Control Centers and Power Panelboard Applications, Safety and Security Systems
Interrupting Rating
200 Kiloamp Symmetrical (AC), 20 Kiloamp (DC)
Features
  • Provides motor overload, ground fault and short circuit protection
  • When used in circuits subject to surge currents such as those caused by motors, transformers and other inductive components, these fuses can be sized close to full-load amps to give maximum over current protection
  • The time delay feature makes it possible to use fuse amperage ratings which are much smaller than those of non-time delay fuses
  • Considerable cost savings occur by permitting the use of smaller size switches, panels and fuses themselves
  • Provides a good deg of short circuit protection (greater current limitation) to help protect downstream components from high fault currents
  • Gives motor running back-up protection to motors without extra cost
  • Helps protect motors against burnout from overloads and single phasing when sized properly
  • Simplifies and improves blackout prevention (selective co-ordination ratios)
  • Dual element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance short circuit and overload protection
Qty Unit price
Ea
1 $167.34

Slpk
1 $167.34

Slqt
1 $167.34

Stpk
1 $167.34

Unit
1 $167.34
Please note: This product is subject to geographic restrictions and can only be sold within the Carolinas.
Bussmann Fusetron™ FRS-R-175 Current Limiting Renewable Time Delay Fuse, 175 A, 600 VAC/300 VDC, 20/200 kA Interrupt, RK5 Class, Cartridge Body