1000 VAC/VDC, 250 A (Aluminum), 310 A (Copper), Mersen EP MPDB69173 Power Distribution Block, 3-Pole

Short Description

5.7" x 7.89" x 3.55", 1000 VAC/VDC, 250 A (Aluminum), 310 A (Copper), Lead-Free, Glass Filled Polycarbonate, 1-Pole 6 to 350 KCMIL AWG Primary, 6-Pole 14 to 2/0 AWG Secondary Wire, Box/Box Connector, 3-Pole, Power Distribution Block

Power Distribution Block; Type Direct Screw Mount, Open-Style; Voltage Rating 1000 Volt AC/DC; Current Rating 250 Amp (Aluminum), 310 Amp (Copper); Number of Poles 3; Number of Primary Openings per Pole 1; Primary Opening Wire Size 350 KCMIL to 6 AWG; Number of Secondary Openings per Pole 6; Secondary Opening Wire Size 2/0 to 14 AWG; Conductor Material Aluminum/Copper; Cover Type Snap-On, Hinged; Size 5.7 Inch Length x 7.89 Inch Width x 3.55 Inch Height; Connector Material Tin Plated Aluminum; Housing Material Glass Filled Polycarbonate; Approval UL 1953, CSA; Lead-Free; RoHS Compliant; Short Circuit Current Rating 100 Kiloamp; Connector Type Box/Box; Hex/Screw Size 11/16 Inch-16 TPI x 0.88 Inch (Primary), 7/16 Inch-20 TPI x 0.55 Inch (Secondary); Hole Diameter 0.75 Inch (Primary), 0.44 Inch (Secondary); Flammability Rating UL 94-V0; Application Cable Splicing, Splitting Primary Power into Secondary Circuit, Fixed Junction Tap-Off Point

MFG #: MPDB69173

EECO #: GFMPDB69173

Brand: Mersen
UPC #: 782001452568
Attributes
Features
Documents
Product Information
Attributes
UNSPSC
39121400
Features
  • RoHS/REACH Compliant
  • Lead-Free
  • Adder Pole for Increased Flexibility and Ease-of-Use, Adder Pole can be Stacked to Form Multi-Pole Unit in the Field without the Use of Tools Adder Pole Allow for Customization of Primary and Secondary Wire Combinations
  • Aluminum Connectors Accept Both Al or Cu Wire While Copper Connectors Accept Cu Wire Only, Connectors are all 1-Piece Tin Plated
  • Insulator is Virtually Unbreakable, Made of Glass Filled Polycarbonate, See-Through Hinged Safety Cover is Optional and Provide a Greater Degree of Safety and Shock Resistance Where Required, Hinged Cover can be Installed without Tools
  • Spacing 1 Inch through Air and 2 Inch over Surface Between Uninsulated Live Parts of Opposite Polarity Meets Requirements for Feeder and Branch Circuit Applications of UL 58A
  • Safety Cover-Polycarbonate Safety Cover Provide Dead-Front Protection, One Cover is Needed for Each Pole, Each Cover has a Test Probe Hole in the Center for Circuit Checking
Qty Unit price
Ea
1 $590.26

Slpk
1 $590.26

Slqt
1 $590.26

Stpk
1 $590.26

Unit
1 $590.26